Global Program Edit

In the mode of [MODE]+PAD7, a setup of PROGRAM, MXER, and EFFECT can be performed globally.


Creating a program

The creation method of a new program

If the [WINDOW] button is pressed when cursor is in the Program field, the window of "Program list" will open.


If F3 (NEW) button is pressed, the window of "New Program" will open.


If F3 (DRUM) button is pressed, if the program of DRUM presses F4 (INST) button, it will create the program of INST (Instruments).


When the program field is "OFF" or "Unused", if cursor button is pressed, a new program will be made automatically.




The type of a program can be changed if a DATA wheel is turned in the type field.



Basic operation in case the type of a program is DRUM
(Refer to video.)


If the cursor button is pressed, cursor will move to the parameter field.


If the [SHIFT]+ cursor button is pressed, cursor will move to the Program field.



The value of a parameter will be copied if the or cursor button is pressed pressing a pad.
(It can do also in [UNDO SEQ] + or )

For example, when you want to copy "Sample01" of A01 to A04 from A02 in the state of the above figure
If cursor is moved to A04 by cursor button, pressing PAD1, the sample of A01 will be copied from A02 to A04.





Moreover, if cursor is moved to A01 by cursor button, pressing PAD4 in the state of the above figure, the result of the following figure will be obtained.


The value of LEVEL of A04 is copied to A03-A01.

If a pad is hit pressing the [UNDO SEQ] button, the value on cursor will be copied to the hit pad.

If PAD2 and PAD4 are hit pressing the [UNDO SEQ] button in the state of the above figure, the result of the following figure will be obtained.


"Sample01" of A01 is copied to A02 and A04.

Copy in a LAYER window

The value of a parameter is copied by a [UNDO SEQ] + or cursor key.
If the [UNDO SEQ] + or cursor key is pressed in the state of the above figure, the value of TUNE will be copied to a layer 2.


Note: A LAYER window will be opened, if cursor is moved to the PAD field and the [WINDOW] button is pushed.

If a pad is hit pressing the [UNDO SEQ] button when cursor is in the PAD field, it will copy to the pad which hit the pad data of the cursor position.

If PAD3 is hit pressing the [UNDO SEQ] button in the state of the above figure, the result of the following figure will be obtained.


All the values of the parameter of A01 are copied to A03. (Copy of a pad)

If the cursor button is pressed, pressing the [SHIFT] button, two or more pads can be chosen.

For example, if cursor is moved to A03 by cursor button, pressing the [SHIFT] button in the state of the above figure, the result of the following figure will be obtained.


When you cancel two or more selections of a pad, please press F6 (ALL) button, pressing the [SHIFT] button.

If F6 (ALL) button is pressed, pressing the [SHIFT] button, the value of the parameter of all the pads can be changed at the same time.

If F6 (ALL) button is pressed, pressing the [SHIFT] button in the state of the above figure, it will become ALL mode as shown in the following figure.


When you cancel ALL mode, please press F6 (ALL) button, pressing the [SHIFT] button.

Note: The value of a parameter can be set also with Q1 slider.

Next page