RECORD |
[MODE]+PAD5(Record mode)
Input field (Select the recording source)
ANALOG: The incoming signal from a RECORD IN terminal
will be recorded.
DIGITAL: The incoming signal from a
DIGITAL IN terminal will be recorded.
MAIN OUT: The same signal as the signal from STEREO OUT
will be recorded.
Mode field
MONO L: Only the incoming signal of a left channel will
be recorded.
MONO R: Only the incoming signal of a right channel will
be recorded.
STEREO: The incoming signal of the channel of the left
and right will be recorded as a sample of a stereo.
MONO L+R: The incoming signal of the channel of the left and
right will be recorded as a sample of a mono.
Monitor field
ON: You can monitor the input signal.
OFF: You cannot monitor the input signal.
Threshold field
After pressing F6 (RECORD) button, if the threshold level which
the level of sauce set is exceeded, recording will be started
automatically.
When F6 (START) button is pressed in this state, recording is
started immediately.
Time field
Please set the recorded time.
The recording ends automatically at the set time.
When time is not set, if recording is started, the time which can
be recorded will be set automatically.
Note field
Please set the note number of the recorded sample.
60(C_3) is set by default.
Reset of a peak hold
A peak hold will be reset if F1 or F2 button is pressed.
Note
When the Input field is MAIN OUT, a level meter does not work.
Starting the recording
Please press F6 (RECORD) button.
If an incoming signal exceeds a threshold level, recording will
be started automatically.
Please press the F6 (START) button when you want to begin
recording at once.
If F5 (CANCEL) button is pressed in this state, it will return to
the state before starting recording.
Recording is stopped at the time set in the time field.
And a "Keep or Retry" window will open.
Even if F6 (STOP) button is pressed, recording stops.
Please set the name of the sample recorded in the New name field.
Please select the pad which assigns the recorded sample in the
PAD field.
If F2 (RETRY) button is pressed, it will return to the state
before removeing the recorded sample and starting recording.
The audition of the sample recorded by pressing F3 (PLAY) button
can be performed.
If F4 (toPAD) button is pressed, the sample recorded to the pad
selected in the PAD field will be assigned, and a window will be
closed. (It returns to the state before starting recording.)
If F5 (KEEP) button is pressed, the recorded sample will not be
assigned to a pad.
And it keep in the memory in MPC.
Sample Memory window
If the WINDOW button is pressed, the window of "Sample
Memory" will open.
The Free memory field displays the time you can record with the
current memory.
Below it, the status of the memory is indicated as bar graph.
Below the bar graph, the total amount of the RAM in the MPC is
displayed.
Note
A note repeat does not work in a record mode.
Moreover, the stop of recording
cannot be performed using a MIDI controller.