Global Program Edit |
In the mode of [MODE]+PAD7,
a setup of PROGRAM, MXER, and EFFECT can be performed globally.
Note
[REC] and the [OVER DUB] button do not work in the mode of Global
Program Edit.
If [REC] or the [OVER DUB] button is pushed, it will return to a
main screen. (INST is also the same)
Creating a program
The creation method of a new program
If the [WINDOW] button is pressed when
cursor is in the Program field, the window of "Program list"
will open.
If F3 (NEW) button is pressed, the window
of "New Program" will open.
If F3 (DRUM) button is pressed, if the
program of DRUM presses F4 (INST) button, it will create the
program of INST (Instruments).
When the program field is "OFF"
or "Unused", if cursor button is pressed, a new program will be made
automatically.
The type of a program can be changed if a DATA wheel is turned in
the type field.
Basic operation in case the type
of a program is DRUM
1 | Selected track number (Active track) |
2 | Set program |
3 | Type of a program (DRUM/INST) |
4 | POLY: Two or more notes can be
pronounced simultaneously. MONO: Two or more notes are not pronounced simultaneously. (Only one note is pronounced.) |
If the cursor button is pressed, cursor will move to the
parameter field.
If the [SHIFT]+ cursor button is pressed, cursor will move to the
Program field.
The value of a parameter will be copied if the or
cursor button is pressed pressing a pad.
(It is possible even if it uses a [UNDO] +
or
button.)
For example, when you want to copy "Sample01"
of A01 to A04 from A02 in the state of the above figure
If cursor is moved to A04 by cursor button, pressing PAD1, the sample of A01 will
be copied from A02 to A04.
Moreover, if cursor is moved to A01 by cursor button, pressing
PAD4 in the state of the above figure, the result of the
following figure will be obtained.
The value of TUNE of A04 is copied to A04-A01.
If cursor button is pressed holding the SHIFT button,
two or more pads can be chosen.
For example, if cursor is moved to A03 by cursor button, holding
the [SHIFT] button in the state of the above figure, the result
of the following figure will be obtained.
When you cancel two or more chosen of a pad,
please press [SHIFT]+F6 (ALL) button.
[SHIFT]+F6 (ALL) button is pressed,
the value of the parameter of all the pads can be changed at the
same time.
If [SHIFT]+F6 (ALL) button is pressed in the state of the above
figure, it will become ALL mode as shown in the following figure.
Please press [SHIFT]+F6 (ALL) button once
again to cancel ALL mode.
If a pad is hit holding the [UNDO] button,
the value on cursor will be copied to the hit pad.
If PAD3 and PAD4 are hit holding the [UNDO]
button in the state of the above figure, the result of the
following figure will be obtained.
"Sample01" of A01 is copied to
A03 and A04.
If a pad is hit holding the [UNDO] button
when cursor is in the PAD field, it will be copied to the pad by
which the value of all the parameters of the pad on cursor was
hit.
If PAD4 is hit holding the [UNDO] button
in the state of the above figure, the result of the following
figure will be obtained.
All the values of the parameter of A01
are copied to A04. (Copy of a pad)
.