SAMPLE

PAD: The pad number is displayed.
SAMPLE: The sample assigned to a pad is set.
DIR: The playback direction of a sample is select.
"FOR" is played back to a forward direction.
"REV" is played back to an reverse direction.
LEVL: The volume of a sample is set.
TUNE: The pitch of a sample is set. (+ /- 3 octave can be set.)
PLAY MODE: ONE SHOT The MPC plays the sample until the end regardless of how long you hold the pad.
NOTE ON The MPC plays the sample only while you hold the pad.
VOICE: It opts for the behavior when pronouncing the same note during a release.
POLY The sound during release pronounces a new note, without erasing.
MONO The sound during release is erased and pronounces a new note.


If cursor is moved to the column of PAD and the [WINDOW] button is pressed, the window of "LAYER" will open.


Please refer to
"Ccopy Pad" for F2 (CopyPad).
Please refer to
"Ccopy Bank" for F3(CpyBank).

Auto chromatic assignment. (PAD of the cursor position is set to TUNE 00.00, and the value of TUNE is fluctuated 01.00 (half tone) every.)

For example, when you want to use one sound, making it into a chromatic scale

Please choose the sample which makes a chromatic scale in the SAMPLE column.


If [SHIFT]+F5 (CHROM.) button is pressed, PAD of the cursor position will be set to TUNE 00.00, and the value of TUNE will be fluctuated 01.00 (half tone) every. (A maximum of +/- 3 octave)
If [SHIFT]+F5 (CHROM.) button is pressed in the case of the above figure, the result of the following figure will be obtained.


PAD of A06 is set to TUNE 00.00, and the value of TUNE is fluctuated 01.00 (half tone) every.
A05-A01 is minus 01.00 (half tone) every, and A07-C10 is plus 01.00 (half tone) every.
In addition, if [SHIFT]+F4 (ClrTUNE) button is pressed, the value of TUNE of all the PAD will be set to 00.00.